0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD

Product Details
Customization: Available
Certification: CE
Protection: Shock Resistance
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Full Customization
The supplier provides full customization services
Private Mold
The supplier has private mold
to see all verified strength labels (16)
  • 0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
  • 0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
  • 0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
  • 0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
ID-10D36CAN-K
Installation
Screw
Housing
Aluminum Package
Measuring Range
0-1000V
Accuracy Class
+-3% & +-3 V
Dimensions
110*45*75mm
Transport Package
Electric Vehicle
Specification
10D36CAN-K
Trademark
OEM
Origin
China
HS Code
9030339000

Packaging & Delivery

Package Size
15.00cm * 9.00cm * 11.00cm
Package Gross Weight
1.000kg

Product Description

0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD

Product Description


Application

* Power battery high voltage system of electric vehicle
* Hybrid electric vehicle high voltage system
* Hydrogen energy vehicle high voltage system
* Energy storage system
* Other DC floating system and AC floating system
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
ID series insulation monitor is used to monitor the insulation resistance of 0~1000Vd.c. DC floating system and 0~750Va.c. AC floating system to ground in real time; measure the insulation fault of equipment shell to ground, high voltage to shell, etc.
In the DC system, the insulation resistance of the positive pole and the negative pole of the DC system to the ground can be independently measured. In specific electric vehicle applications, insulation resistance can also be reliably monitored under strong interference or complex driving conditions, such as acceleration/deceleration, braking, and energy recovery.
In the AC system, it can suppress the interference of voltage high-frequency harmonics, and accurately measure the insulation resistance of the entire AC system to ground.

Features

* DC system: monitor the ground insulation of the 0~1000Vd.c. DC floating system
* AC system: Monitor the ground insulation of 0~750Va.c. AC floating system
* Passive equipment: monitor the insulation status between the equipment and the housing or between the equipment and the ground
* When the bus voltage is 0, the insulation resistance of the system to ground can still be reliably monitored
* Measuring range 0~50 MΩ, when it exceeds 50 MΩ, the default output is 50 MΩ
* Automatic adaptation system Y capacitor CY (CY≤4 μF)
* CAN bus interface
* Built-in high-voltage relay can disconnect the physical connection between the terminal (DC+/DC-) of the insulation monitor and the system under test

Dimensions(mm):
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMDTypical application scenarios
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
Product Parameters
Accuracy
1%
Measurement range
0-1000VDC
0-750VAC
Power supply
9-36VDC
Input power
≤ 2W
Insulation resistance
0 ~ 50 MΩ (Default is 50 MΩ when over 50 MΩ)
Insulation accuracy
±12 kΩ (@ 0~100 kΩ, CY≤ 2μF)
±10 % (@100 kΩ~1 MΩ, CY≤ 2μF)
±10 % (@1MΩ~50MΩ, CY≤ 2μF)
Response time
4s (@RISO≥ 500 kΩ, CY =0μF)
5s (@RISO<500 kΩ, CY =0μF)
8s (@RISO=1MΩ, CY =1μF)
12s (@RISO=1MΩ, CY =2μF)
High voltage input resistance
Positive 5 MΩ,Negative 1 MΩ to ground (@Internal high voltage relay closed)
Positive& negative poles to ground over 500 MΩ (@Internal high voltage open)
Pulse signal amplitude
±15 V
Pulse signal frequency
Adaptive
Isolation withstand voltage
3500VDC, 2500VAC (RMS)
Operating temperature
-40 ºC~+85 ºC
Storage temperature
-40 ºC~+85 ºC
IP protection
IP 55
Weight
0.5kg (Aluminum package)

Selection precautions:
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier