Certification: CE
Protection: Shock Resistance
Installation: Screw
Samples:
US$ 180/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD pictures & photos
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
US $120-150 / Piece
Min. Order: 10 Pieces
Manufacturer/Factory, Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Beijing, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Full Customization
The supplier provides full customization services
Private Mold
The supplier has private mold
to see all verified strength labels (16)
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
ID-10D36CAN-K
Housing
Aluminum Package
Measuring Range
0-1000V
Accuracy Class
+-3% & +-3 V
Dimensions
110*45*75mm
Transport Package
Electric Vehicle
Specification
10D36CAN-K
Trademark
OEM
Origin
China
HS Code
9030339000

Packaging & Delivery

Package Size
15.00cm * 9.00cm * 11.00cm
Package Gross Weight
1.000kg
Lead Time
20 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD

Product Description


Application

* Power battery high voltage system of electric vehicle
* Hybrid electric vehicle high voltage system
* Hydrogen energy vehicle high voltage system
* Energy storage system
* Other DC floating system and AC floating system
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
ID series insulation monitor is used to monitor the insulation resistance of 0~1000Vd.c. DC floating system and 0~750Va.c. AC floating system to ground in real time; measure the insulation fault of equipment shell to ground, high voltage to shell, etc.
In the DC system, the insulation resistance of the positive pole and the negative pole of the DC system to the ground can be independently measured. In specific electric vehicle applications, insulation resistance can also be reliably monitored under strong interference or complex driving conditions, such as acceleration/deceleration, braking, and energy recovery.
In the AC system, it can suppress the interference of voltage high-frequency harmonics, and accurately measure the insulation resistance of the entire AC system to ground.

Features

* DC system: monitor the ground insulation of the 0~1000Vd.c. DC floating system
* AC system: Monitor the ground insulation of 0~750Va.c. AC floating system
* Passive equipment: monitor the insulation status between the equipment and the housing or between the equipment and the ground
* When the bus voltage is 0, the insulation resistance of the system to ground can still be reliably monitored
* Measuring range 0~50 MΩ, when it exceeds 50 MΩ, the default output is 50 MΩ
* Automatic adaptation system Y capacitor CY (CY≤4 μF)
* CAN bus interface
* Built-in high-voltage relay can disconnect the physical connection between the terminal (DC+/DC-) of the insulation monitor and the system under test

Dimensions(mm):
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMDTypical application scenarios
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
Product Parameters
Accuracy
1%
Measurement range
0-1000VDC
0-750VAC
Power supply
9-36VDC
Input power
≤ 2W
Insulation resistance
0 ~ 50 MΩ (Default is 50 MΩ when over 50 MΩ)
Insulation accuracy
±12 kΩ (@ 0~100 kΩ, CY≤ 2μF)
±10 % (@100 kΩ~1 MΩ, CY≤ 2μF)
±10 % (@1MΩ~50MΩ, CY≤ 2μF)
Response time
4s (@RISO≥ 500 kΩ, CY =0μF)
5s (@RISO<500 kΩ, CY =0μF)
8s (@RISO=1MΩ, CY =1μF)
12s (@RISO=1MΩ, CY =2μF)
High voltage input resistance
Positive 5 MΩ,Negative 1 MΩ to ground (@Internal high voltage relay closed)
Positive& negative poles to ground over 500 MΩ (@Internal high voltage open)
Pulse signal amplitude
±15 V
Pulse signal frequency
Adaptive
Isolation withstand voltage
3500VDC, 2500VAC (RMS)
Operating temperature
-40 ºC~+85 ºC
Storage temperature
-40 ºC~+85 ºC
IP protection
IP 55
Weight
0.5kg (Aluminum package)

Selection precautions:
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD pictures & photos
0-1000V Can Bus Electric Vehicle EV DC Insulation Resistance Monitoring Device IMD
US $120-150 / Piece
Min. Order: 10 Pieces
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Type of Ownership
Limited Company
Plant Area
501~1000 square meters